EMSEAL
Expansion Joints and Pre-Compressed Sealants


Products: Building Expansion Joints and Sealants

 

WALL SYSTEMS
COLORSEAL-ON-A-REEL
COLORSEAL-ON-A-REEL
Primary Seal for small joints
80% Movement
1/2" to 1"
10-ft per reel

Use instead of caulk-and-backer rod

COLORSEAL
COLORSEAL
Primary and Secondary Seal
50% Movement
1/2" to 8"

SEISMIC COLORSEAL
SEISMIC COLORSEAL
Primary Seal
100% Movement
1/2" to 10"

SEISMIC COLORSEAL-DS
SEISMIC COLORSEAL DS
Seals both sides of joint
Primary Seal
100% Movement
1" to 10"

EMSHIELD WFR2
EMSHIELD WFR3

EMSHIELD WFR2 and WFR3
2hr built in fire rating (UL,ULC)
50% movement
1" to 6"

EMSHIELD SecuritySeal SSW2
SecuritySeal SSW2
Pick Resistant
2hr fire rating(UL,ULC)
50% movement
1" to 6"

BACKERSEAL
BACKERSEAL
Secondary Seal to Field Applied Liquid Sealant
50% Movement
1/4" to 1 1/4"

Order/Inquiry Checklist

Lead Times

DECKS SOLID SLAB
COLORSEAL-ON-A-REEL
COLORSEAL-ON-A-REEL
Primary Seal for small joints
80% Movement
1/2" to 1"
10-ft per reel

Use instead of caulk-and-backer rod

DSM SYSTEM
DSM SYSTEM
Joint-face adhered
Blockouts Optional
55% Movement
1/2" to 4"

SJS SYSTEM
SJS-SEISMIC JOINT SYSTEM
Joint-face adhered
Sound dampened
Integral coverplate
Up to 100% Movement
4" to 18"

EMSHIELD DFR2
EMSHIELD DFR2
2hr Built-In Fire Rating (UL,ULC)
Joint-face adhered
100% Movement
1/2" to 4"

EMSHIELD DFR2
2hr or 3hr Built-In Fire Rating (UL,ULC)
Joint-face adhered
100% Movement
1/2" to 4"

EMSHIELD DFR3
EMSHIELD DFR3
3hr Built-In Fire Rating (UL,ULC)
Joint-face adhered
50% Movement
1/2" to 4"

EMSHIELD DFR3
3hr Built-In Fire Rating (UL,ULC)
Joint-face adhered
50% Movement
1/2" to 4"

EMSHIELD SJS-FR1 and SJS-FR2
EMSHIELD SJS-FR1 and SJS-FR2
1hr or 2hr Built-In Fire Rating
Sound Dampened
Integral Coverplate
100% movement
4" to 10"

EMSHIELD SJS-FR1 and SJS-FR2
1hr or 2hr Built-In Fire Rating
Sound Dampened
Integral Coverplate
100% movement
4" to 10"

EMSHIELD SJS-FR1 and SJS-FR2
1hr or 2hr Built-In Fire Rating
Sound Dampened
Integral Coverplate
100% movement
4" to 10"

EMSHIELD SecuritySeal SSF2

EMSHIELD SecuritySeal SSF2
Pick Resistant, Tamper Resistant
2hr Built-In Fire Rating (UL,ULC)
100% movement
1/2" to 4"

EMSHIELD SecuritySeal SSF3
EMSHIELD SecuritySeal SSF3
Pick Resistant, Tamper Resistant
3hr Built-In Fire Rating (UL,ULC)
50% movement
1/2" to 4"

HORIZONTAL COLORSEAL
HORIZONTAL COLORSEAL
Joint-face adhered
Non Trafficable
100% movement
1/2" to 10"

THERMAFLEX
THERMAFLEX
Blockout-Mounted, Adhered
Car, Pedestrian Traffic
Movement varies by model
1" to 5-1/2" max

EMCRETE
EMCRETE
Elastomeric Nosing and
Patching Material
1:2 Resin to Aggregate by Weight
Flexible. Impact and Sound Absorbing

DECKS SPLIT SLAB
MIGUTAN FP-Series
MIGUTAN FP-Series
Heat-Weldable Sealing Insert
Heat-Weldable Waterproofing Side Sheets
Optional Coverplates
Movement Varies By Model
1/2" to 6" max. Mean Joint

DSM FP SYSTEM
DSM FP SYSTEM
Silicone-Coated, Precompressed Foam Sealing Element
Optional Coverplates
55% Movement
Up to 4" max. Mean Joint

EMSHIELD DFR FP SYSTEM
DFR FP SYSTEM
Silicone-Coated, Precompressed Foam Sealing Element
UL Fire-Rated
50% Movement
Up to 4" max. Mean Joint

SJS FP SYSTEM
SJS FP SYSTEM
Silicone-Coated, Precompressed foam and
integral aluminum spline, sealing assembly
Integral Coverplate
100% Movement
1/2" to 18" max. Mean Joint

EMSHIELD SJS-FP-FR2 SYSTEM
EMSHIELD SJS-FP-FR2 SYSTEM
Fire Rated, Silicone-Coated, Precompressed foam and
integral aluminum spline, sealing assembly
Integral Coverplate
100% Movement
4" to 10" max. Mean Joint

 

EMSHIELD FIRE-RATED
EMSHIELD WFR2 and WFR3
EMSHIELD WFR2 and WFR3
2hr built in fire rating (UL,ULC)
50% movement
1" to 6"
 

EMSHIELD SecuritySeal SSW2
SJS-SEISMIC JOINT SYSTEM
Joint-face adhered
Sound dampened
Integral coverplate
Up to 100% Movement
4" to 18"

EMSHIELD DFR2
EMSHIELD DFR2
2hr Built-In Fire Rating (UL,ULC)
Joint-face adhered
100% Movement
1/2" to 4"

EMSHIELD DFR2
2hr or 3hr Built-In Fire Rating (UL,ULC)
Joint-face adhered
100% Movement
1/2" to 4"

EMSHIELD DFR3
EMSHIELD DFR3
3hr Built-In Fire Rating (UL,ULC)
Joint-face adhered
50% Movement
1/2" to 4"

EMSHIELD DFR3
3hr Built-In Fire Rating (UL,ULC)
Joint-face adhered
50% Movement
1/2" to 4"

EMSHIELD DFR FP SYSTEM
DFR FP SYSTEM
Silicone-Coated, Precompressed Foam Sealing Element
UL Fire-Rated
50% Movement
Up to 4" max. Mean Joint

EMSHIELD SJS-FR1 and SJS-FR2
EMSHIELD SJS-FR1 and SJS-FR2
1hr or 2hr Built-In Fire Rating
Sound Dampened
Integral Coverplate
100% movement
4" to 10"

EMSHIELD SJS-FR1 and SJS-FR2
1hr or 2hr Built-In Fire Rating
Sound Dampened
Integral Coverplate
100% movement
4" to 10"

EMSHIELD SecuritySeal SSF2

EMSHIELD SecuritySeal SSF2
Pick Resistant, Tamper Resistant
2hr Built-In Fire Rating (UL,ULC)
100% movement
1/2" to 4"

EMSHIELD SecuritySeal SSF3
EMSHIELD SecuritySeal SSF3
Pick Resistant, Tamper Resistant
3hr Built-In Fire Rating (UL,ULC)
50% movement
1/2" to 4"

EMSHIELD SJS-FP-FR2 SYSTEM
EMSHIELD SJS-FP-FR2 SYSTEM
Fire Rated, Silicone-Coated, Precompressed foam and
integral aluminum spline, sealing assembly
Integral Coverplate
100% Movement
4" to 10" max. Mean Joint
 

 

ROOFS
ROOFJOINT
RoofJoint
Dual Flanged,
Redundant Sealing, Watertight
Roof Expansion Joint
with Roof To Wall Joint Transitions
100% Movement
2" to 4"


BELOW GRADE
DSM SYSTEM
DSM SYSTEM
Postive Side
Negative Side As Grout Containment
55% Movement
1/2" to 8"

DSM-DS SYSTEM
DSM-DS SYSTEM
Negative Side with Drainage
Double-Sided DSM
55% Movement
1/2" to 8"

20H SYSTEM
20H SYSTEM
Positive Side
Acrylic/Asphalt Impregnated
Precompressed Foam with Epoxy Adhesive
50% Movement
1/2" to 8"

BG SYSTEM
BG SYSTEM
Blind Side Walls on Lagging
Extruded Thermoplastic
Embeds into positive or blind-side,
below-grade waterproofing membranes
100% Movement
2"


SUBMERGED / NSF
SUBMERSEAL
SUBMERSEAL
NSF-61 Silicone Coated
Precompressed
Chlorine and Saline Resistant
Head Pressure Tested
50% Movement
1/2" to 4"

DSF-SYSTEM
CHEMSEAL

 

INTERIOR
ALL INTERIOR
All Interior Joints Index
Heavy, Standard, and Medium Duty
Surface and Blockout Mounted
Solid Aluminum and Metal/Rubber Options
Movement Varies With Model
3/4" to 24"

Surface Mounted
Surface Mounted Floor Joints
Quick Installation
Low Profile
Flush, Carpet, Tile Versions
Movement Varies With Model
3/4" to 24"

QuietJoint
QuietJoint
Interior Partition Seal
Sound, Draft, Heat, Cold, Dust Blocker
STC 53, OITC 38
26 Colors
Not For Movement Joints
1/2" to 6"

EMSHIELD WFR2 and WFR3
EMSHIELD WFR2 and WFR3
2hr or 3hr built in fire rating (UL,ULC)
50% movement
1" to 6"
 

EMSHIELD SecuritySeal SSW2
SecuritySeal SSW2
Pick Resistant
2hr fire rating(UL,ULC)
50% movement
1" to 6"

EMSHIELD DFR2
EMSHIELD DFR3
EMSHIELD DFR2 and DFR3
2hr or 3hr Built-In Fire Rating (UL,ULC)
Joint-face adhered
50% Movement
1/2" to 4"

EMSHIELD DFR2 and DFR3
2hr or 3hr Built-In Fire Rating (UL,ULC)
Joint-face adhered
50% Movement
1/2" to 4"

EMSHIELD SJS-FR1 and SJS-FR2
EMSHIELD SJS-FR1 and SJS-FR2
1hr or 2hr Built-In Fire Rating
Sound Dampened
Integral Coverplate
100% movement
4" to 10"

EMSHIELD SecuritySeal SSF2
EMSHIELD SecuritySeal SSF3
EMSHIELD SecuritySeal SSF2 and SSF3
Pick Resistant
2hr or 3hr Built-In Fire Rating (UL,ULC)
50% movement
1/2" to 4"
 

 

 


The EMSEAL CHECKLIST

(For help in making a product selection, or to accompany an order
click this link to open, complete, and email our new universal checklist).

CHECKLIST (en español)
 

 
 

EMSEAL JOINT SYSTEMS LTD. 25 Bridle Lane, Westborough, MA 01581
EMSEAL LLC. 120 Carrier Drive, Toronto, ON M9W 5R1

   

 


1-800-526-8365 -- 508-836-0280 --  techinfo@emseal.com -- Fax: 508-836-0281

Last Modified: October 31, 2014

Copyright © 1998-2014 by EMSEAL Joint Systems, Ltd. All rights reserved.
This document may not be reproduced in whole or in part without permission.