Selection Guide: Stadium
Stadium expansion joint solutions - watertight from foundation, to concourses, to walls, seating bowl and roof.
Stadium Seating Bowl
Expansion joint systems engineered for stadium seating bowls, combining watertight performance, fire resistance, durability, and movement capability to withstand weather exposure and heavy pedestrian traffic.
Description
- 2 -Hour, Built-In Fire-Rating (UL 2079)
Details
1/2″ to 4″
(12 – 100mm)
100% Movement (+50%/-50%)
Description
- Joint face adhered
- Sound-dampening-nosing blockouts available
- Integral coverplate
- Non-invasively anchored
Details
2″ to 16″
(50 – 400mm)
100% Movement (+50%/-50%)
Description
- 1 or 2-Hour, Built-In Fire-Rating (UL 2079)
- Integral coverplate
- Non-invasively anchored
Details
2″ to 10″
(50 – 250mm)
100% Movement (+50%/-50%)
Stadium Concourse -- Solid Slab
Description
- 2 -Hour, Built-In Fire-Rating (UL 2079)
Details
1/2″ to 4″
(12 – 100mm)
100% Movement (+50%/-50%)
Description
- Joint face adhered
- Sound-dampening-nosing blockouts available
- Integral coverplate
- Non-invasively anchored
Details
2″ to 16″
(50 – 400mm)
100% Movement (+50%/-50%)
Description
- 1 or 2-Hour, Built-In Fire-Rating (UL 2079)
- Integral coverplate
- Non-invasively anchored
Details
2″ to 10″
(50 – 250mm)
100% Movement (+50%/-50%)
Description
- Blockout mounted
- Steel reinforced EPDM flanges
- Heavy vehicular and forklift durable
Details
1″ to 6″ max.
(25 – 150mm)
Description
- Flexible
- Sound dampening
- Slip-Resistant
- Rugged and durable
- Easy installation
Details
- Plate Width / Joint Opening Max
- 12″ (305mm) / 6″ (150mm)
- 18″ (450mm) / 11″ (280mm)
- 17-1/2″ (445mm) / 12″ (305mm)
- 23-1/2″ (590mm) / 18″ (455mm)
- 29-3/4″ (755mm) / 24″ (610mm)
- 36-3/4″ (680mm) / 31″ (785mm)
Description
- Flexible
- Sound dampening
- Slip-Resistant
- Rugged and durable
- Recess mounted
Details
- Model / Joint Opening Max
- SSF-200/400 / 8.5″ (215mm)
- SSF-600/800 / 16″ (405mm)
- SSF-1000/1200 / 23″ (585mm)
- SSF-1800/2000 / 28.5″ (725mm)
- SSF-2200/2400 / 36″ (915mm)
Stadium Concourse -- Split Slab
Description
- For fire-rated, split-slabs, plaza decks, podium decks
- 2-hour built-in fire-rating
- Watertight integration with deck waterproofing membrane
Details
up to 4″
(100mm)
max. mean join
100% Movement (+50%/-50%)
Description
- For split-slabs, plaza decks, podium decks
- Up to 2-hour built-in fire-rating
- Watertight integration with deck waterproofing membrane
Details
2″ to 10″
(50 – 250mm)
100% Movement (+50%/-50%)
Description
- Ideal for plaza to solid slab conditions
- Watertight integration at structural slab
- Silicone coated, precompressed foam sealing element
- Optional coverplates
Details
up to 4″
(100mm)
max. mean joint
100% Movement (+50%/-50%)
Description
- Watertight
- Watertight integration with deck waterproofing membrane
- Factory heat-welded transitions ensure continuity of seal
- Optional coverplates
Details
Up to 4.75-inch (120mm)
max. mean joint
Movement varies with model
Stadium Walls
Description
- Primary Seal
- R-Value
- Sound Attenuation
- 26 colors
Details
1/2″ to 10″
(12 – 250mm)
100% Movement (+50%/-50%)
Description
- Retrofit joint sealant for EIFS, precast, concrete, and virtually any substrate
- Safe and rapid installation without the requirement for grinding
- Smooth convex surface
- Paintable and coatable
Details
1/2″ to 1 1/4″
(12 – 30mm)
100% movement (+/- 50%)
Use in Joint Range:
3/8” – 1-1/2”
(10 – 40mm)
Description
- Watertight and fire rated
- 2-Hour, built-in fire-rating (UL 2079)
- Seals both sides of joint
- Many industry colors
Details
1/2″ to 6″
(12 – 150mm)
100% Movement (+50%/-50%)
Description
- Pick-resistant
- Watertight and fire rated
- 2-Hour, built-in fire-rating (UL 2079)
- Seals both sides of joint
Details
1/2″ to 6″
(12 – 150mm)
100% Movement (+50%/-50%)
Description
- Primary seal in paintable hybrid or silicone sealant
- Smooth convex surface
- Low cost
- Rapid install alternative to caulk & backer rod
Details
1/2″ to 1 1/4″
(12 – 30mm)
80% Movement (+30%/ -50%)
Description
- Double-sided DSM
- Silicone-coated on both faces
- Simple installation in unique applications
Details
1/2″ to 4″
(12 – 200mm)
(Larger sizes consult Emseal)
Description
- Single installation seals both sides of joint
- Ideal for curtainwall, precast
- Customized to depth of substrate
Details
1/2″ to 10″
(12 – 250mm)
100% Movement (+50%/-50%)
Description
Anodized aluminum
Surface/Flush mounted options
Details
Joint size:
1″ – 6″ (25mm – 150mm)
Movement:
>100% total
Description
Anodized aluminum
Surface/Flush mounted options
Details
Joint size:
1″ – 4″ (25mm – 100mm)
Movement:
100% total
Description
Aluminum with colored elastomeric gland
Flush mounted
Details
Joint size:
NBW = 4″ – 24″ (100 – 610mm)
NBS = 2″ – 24″ (50 – 610mm)
Movement:
>100% total
Description
Anodized aluminum cover
Surface mounted
Details
Joint sizes:
WFE/WFX (exterior): 10″ – 24″ (255 – 610mm)
WFI (interior): 2″ – 24″ (50 – 610mm)
WFT (interior): 4″ – 24″ (100 – 610mm)
Stadium Interior Floors
Description
- 1 or 2-Hour, Built-In Fire-Rating (UL 2079)
- Integral coverplate
- “No Bump” option ensures smooth rolling surface
- “Infill” option receives flooring for aesthetic integration
- Non-invasively anchored
- Integrates into flooring
Details
2″ to 10″
(50 – 250mm)
100% Movement (+50%/-50%)
Description
- 1 or 2-Hour, Built-In Fire-Rating (UL 2079)
- Integral coverplate
- Non-invasively anchored
Details
2″ to 10″
(50 – 250mm)
100% Movement (+50%/-50%)
Description
Solid aluminum
Recess mount
Heavy load rating
Details
Joint sizes up to:
3/8″ – 4″ (10 – 75mm)
Movement:
Varies by Model
Description
Solid aluminum
Recessed/Surface mounted options
Medium load rating
Details
Joint sizes:
FJF = 1″ – 6″ (25mm – 150mm)
FJS = 2″ (50mm)
Movement:
FJF = >100% total
FJS = 50% total
Description
Aluminum with colored elastomeric gland
Flush mounted
Details
Joint size:
NBW = 4″ – 24″ (100 – 610mm)
NBS = 2″ – 24″ (50 – 610mm)
Movement:
>100% total
Description
Solid aluminum w/ stainless-steel options
Recessed mounted flush
Medium-heavy load rating
Details
Joint sizes:
2″ – 24″ (50mm – 610mm)
Movement:
>100% total
Description
Aluminum seismic pan for flooring infill
Recess mounted
Details
Joint sizes:
2″ – 18″ (50 – 455mm)
Stadium Roofs
Description
- High movement
- Redundant sealing and fastening
- Double-level roof-membrane integration flanges
- UV-stable
- Seals roof-to-wall interface
- Factory-fabricated transitions ensure continuity of seal
Details
RJ-0200: 2-3 inches (50-75mm)
RJ-0400: 3-5 inches (75-125mm)
RJ-0600: 5-7 inches (125-175mm)
RJ-0800: 7-9 inches (175-225mm)
Movement
RJ-0200: 2 1/2 inches (60mm)
RJ-0400: 5 inches (125mm)
RJ-0600: 7 inches (175mm)
RJ-0800: 9 inches (225mm)
Below-grade / Foundation
Description
- Extruded Nitrile-PVC extrusion with dual-level membrane integration flanges
- Flanges are welded or adhered to below-grade waterproofing membrane and fastened with termination bar and anchors
- Transitions to RoofJoint in softscapes, and FP-Systems in hardscapes
Details
2″ up to 7″
(50 – 175mm)