STADIUM BOWL:
|
|

|
DSM SYSTEM |
Treads and Risers up to 4" •
New or Retrofit
• 55%
Movement (+30/-25%)
• Joint-face adhered
•
Blockouts optional
|
1/2" to 4" max.
(12 - 100mm)
|
 |
SJS SYSTEM |
Treads &
Risers 4" and up
• New or Retrofit
• 100% Movement (+/-50%)
• Joint face adhered
• Sound-dampening-nosing
blockouts
recommended
• Integral coverplate |
4"
to 24"
(100 - 600mm) |
 |
THERMAFLEX |
Treads and Risers
up to 5", >55% movement
• New or Retrofit
• up 130% Movement (+/-50%)
• Blockout Mounted |
1" to 5-1/2" max.
(25 - 140mm)
|
|
FIRE-RATED CONCRETE BOWLS and SOLID-SLAB CONCOURSES:
|
|

|
EMSHIELD
DFR2 and DFR3 |
Fire-Rated
Treads and Risers up to 4"
• 2-Hour, Built-In
Fire-Rating (UL 2079)
• 50% Movement (+/-25%)
• Joint face adhered
•
Blockouts optional |
1/2" to 4"
(12 - 100mm)
|
 |
EMSHIELD
SJS-FR1 and
SJS-FR2 |
Fire-Rated Treads and Risers 4" and
up • 1 or
2-Hour, Built-In Fire-Rating (UL 2079)
• 100% Movement (+/-50%)
• Sound-dampening-nosing
blockouts
recommended
• Integral coverplate |
4" to 10"
(100 - 250mm) |
|
STADIUM CONCOURSES--SOLID-SLAB:
|
 |
DSM SYSTEM |
Solid-Slab Concourses
up to 4"
• New or Retrofit
• 100% Movement (+/-50%)
• Joint face adhered
• Impact-absorbing-nosing
blockouts
recommended
• Integral coverplate |
1/2" to 4" max.
(12 - 100mm)
|
 |
THERMAFLEX |
Solid-Slab Concourses
up to 5"
• New or Retrofit
• up 130% Movement (+/-50%)
• Joint face adhered |
1" to 5-1/2" max.
(25 - 140mm)
|
 |
SJS SYSTEM |
Solid-Slab Concourses
4" and up
• New or Retrofit
• 100% Movement (+/-50%)
• Joint face adhered
• Sound-dampening-nosing
blockouts
recommended
• Integral coverplate |
4"
to 24"
(100 - 600mm) |
|
STADIUM CONCOURSES--SPLIT-SLAB:
|
 |
DSM
FP SYSTEM |
Split-Slab Concourses
up to 4"--50% Movement • 55%
Movement (+30/-25%)
• Silicone coated, precompressed foam sealing element
• Optional coverplates |
up
to 4"
(100mm)
max. mean joint |
 |
MIGUTAN FP/...Series |
Split-Slab Concourses
up to 4" joint gaps->50% Movement • Movement
varies by model
• Extruded Santoprene sealing element
• Optional coverplates |
Up to 6-inch (150mm)
max.
mean joint.
|
 |
SJS FP SYSTEM |
Solid-Slab Concourses
up to 18" joint gaps • 100%
Movement (+/-50%)
• Silicone coated, precompressed foam and integral aluminum spline,
sealing assembly
• Integral coverplate |
up to
18"
(450mm)
max. mean joint |
 |
EMSHIELD
SJS-FP-FR2 |
NEW...Fire-Rated... • For
Split-Slabs, Plaza Decks, Podium Decks
• Up to 2-Hour Built-In Fire-Rating
• Watertight integration with deck waterproofing
• 100% Movement (+/-50%) |
4"
to 10"
(100 - 250mm) |
|
PRECAST CONNECTIONS and Other Small
Joints:
|
 |
DSM SYSTEM |
Replace all caulk-and-backer-rod joints •
New or Retrofit
• 55%
Movement (+30/-25%)
• Joint-face adhered
•
Blockouts optional
• Tensionless |
1/2" to 4" max.
(12 - 100mm) |
|
STADIUM WALLS: Suite, Concession, Locker and
Utility Room, Exterior Perimeter |
 |
SEISMIC COLORSEAL |
Suite, Concession, Locker and
Utility Room Walls
• 100% Movement
(+/-50%)
• Primary Seal
• R-Value
• Sound Attenuation |
3/8"
to 12"
(8 - 300mm) |
|
 |
EMSHIELD WFR2 |
Fire-Rated
Suite, Concession, Locker and Utility Room Walls
• 2-Hour,
Built-In Fire-Rating (UL 2079)
• 50% Movement (+/-25%)
• Seals both sides of joint |
1/2" to 6"
(12 - 150mm) |
 |
SECURITY SEAL SSW2 |
Vandal-Prone, Fire-Rated
Suite, Concession, Locker and Utility Room Walls
• Pick-Resistant
• 2-Hour, Built-In Fire-Rating (UL 2079)
• 50% Movement (+/-25%)
• Seals both sides of joint |
1/2" to 6"
(12 - 150mm) |
 |
SEISMIC COLORSEAL
DS (Double Sided) |
Shallow-Depth, Both Faces Sealed
Suite, Concession, Locker
and Utility Room Walls
• 100%
Movement (+/-50%)
• Seals both sides of joint |
1"
to 12"
(25 - 300mm) |
 |
SEISMIC COLORSEAL
DS (Double Sided) |
Shallow-Depth Knee-Walls and Parapets
• 100%
Movement (+/-50%)
• Seals both sides of joint |
1"
to 12"
(25 - 300mm) |
|
INTERIOR FLOORS--Suites, Hallways,
Locker Rooms,etc:
|
 |
MIGUTRANS
FS-Series |
Interior,
High-Point-Load Floors |
|
| |
|
|
|